Thursday, July 24, 2014

iLO 4 causes PSOD

A majority of the environments I work on are HP, Cisco UCS, or Dell servers these days. Not in any particular order, but that just seems to be what I see the most of. I have been seeing a lot of activity related to an issue I have not personally run into but HP has released a tech bulletin on. That issue is related to HP's iLO 4 firmware. The issue seems to be the following;

"HP iLO 4 may experience Intermittent Non-Maskable Interrupt (NMI) Events on Proliant G8 Servers with HP iLO 4 firmware versions 1.30, 1.32, 1.40 and 1.50."

If you experience these NMI events it is possible for bad things to happen on your OS

  • VMware ESXi hosts may experience Purple Screen of Death (PSOD)
  • Linux Operating Systems will display a Message indicating an NMI occurred
  • Microsoft Windows will experience a Blue Screen of Death (BSOD)

HP's Tech Bulletin concerning this issue can be located here
HP's solution to this issue is to update to iLO 4 version 1.51 or later, 1.51 can be found here

Friday, July 18, 2014

VTUG New England Summer Slammer 2014!!

Big thanks to everyone for coming to the Focus booth at VTUG yesterday. Also a special thanks to those who sat in on my Troubleshooting tips for View breakout session.

-Brad